Título: PROCEDIMENTO VOLTAMÉTRICO OTIMIZADO PARA DETERMINAÇÃO DE Ni2+ EM AMOSTRAS PRÉ-TRATADAS DE BIODIESEL, USANDO ELETRODO MODIFICADO COM FILME DE MERCÚRIO
Título(s) alternativo(s): PROCEDURE OPTIMIZED VOLTAMMETRIC FOR DETERMINATION OF Ni2 + IN PRE-TREATED SAMPLES OF BIODIESEL, USING MODIFIED ELECTRODE WITH FILM OF MERCURY
Autor: Nobre, Eva Michelly Carvalho Santana 
Primeiro orientador: LACERDA, Cristina Alves
Resumo: A presença de metais no biodiesel pode estar relacionada com a matéria-prima, com o processo utilizado para a obtenção do biodiesel ou com sua estocagem e pode provocar reações de oxidação, corrosão e entupimento em motores, além de causar riscos à saúde humana e ao meio ambiente. Neste trabalho, é proposto um procedimento voltamétrico com base em condições experimentais adequadas para a determinação do íon Ni2+ em biodiesel (B100) por Voltametria Adsortiva de Redissolução no modo Onda Quadrada, usando o eletrodo de Filme de Mercúrio preparado no modo ex situ. Inicialmente, o filme de mercúrio foi preparado e a seguir realizaram-se as análises com amostra de biodiesel pré-tratada (digerida). A digestão da amostra foi realizada com forno de micro-ondas em sistema fechado, na presença de ácido nítrico ultra-puro e peróxido de hidrogênio. Após essa etapa, foi adicionado tampão amônia 0,01 mol L-1 pH 9,23 e NaOH 0,46 mol L-1 na célula para ajustar o pH da amostra para um valor final de aproximadamente 9,2. Por fim, foi adicionado o quelante dimetilglioxima (DMG) 0,01mol L-1 que funciona como complexante para captura do íon Ni2+. Após esta etapa, vários experimentos voltamétricos, na ausência e presença de alíquotas crescentes de biodiesel e solução padrão do íon metálico foram realizados para otimizar as condições de análise. Os resultados obtidos indicam que a Voltametria Adsortiva de Redissolução no modo Onda Quadrada (VAdRSWV) apresentou resultado satisfatório para medidas do metal traço em Biodiesel (B100), em concentrações de até 10-8 mol L-1. Os experimentos realizados pela adição sucessiva de alíquotas de uma solução padrão do íon Ni2+ proporcionaram uma resposta linear da corrente de pico com a concentração do íon metálico. Cada amostra de biodiesel foi analisada em triplicata, apresentando resultados bastante satisfatórios do ponto de vista analítico por se tratar de análise de elementos traços, principalmente, em termos de exatidão (recuperação de 105 %) e precisão (DPR de 9,61%), para o íon metálico Ni2+, utilizando um limite de confiança de 98%.
Abstract: The presence of metals in biodiesel can be related to raw material, the process used to obtain biodiesel or its storage and can cause reactions of oxidation, corrosion and clogging engines, besides causing risks to human health and the environment. In this paper, we propose a procedure based on voltammetric experimental conditions suitable for the determination of Ni2+ ion in biodiesel (B100) through Square Wave Adsorptive Stripping Voltammetry, using the mercury film electrode prepared ex situ. First, the mercury film was prepared and then was conducted the analysis of a biodiesel pre-treated (digested) sample. The sample digestion was performed with microwave oven in a closed system in the presence of ultra-pure nitric acid and hydrogen peroxide. After this, ammonia buffer 0.01 mol L-1 pH 9.23 and NaOH 0.46 mol L-1 was added into the cell to adjust the pH of the sample to a final value of approximately 9.2. Finally, the chelator dimethylglyoxime (DMG) 0.01 mol L-1 was added, which acts as a complexing element to capture the Ni2+ ion. Next, several voltammetric experiments, in the absence and presence of increasing aliquots of biodiesel and standard solution of the metallic ion, were performed to optimize the analysis conditions. The results indicate that the Square Wave Adsorptive Stripping Voltammetry (VAdRSWV) appeared suitable for measurements of trace metal in Biodiesel (B100) in concentrations up to 10-8 mol L-1. The experiments carried out by successive addition of aliquots of a standard solution of Ni2+ ions provided a linear response of peak current with the concentration of metal ion. Each sample of biodiesel was analyzed in triplicate, with very satisfactory results from the analytical point of view, once we were dealing with trace element analysis, especially in terms of accuracy (recovery 105%) and precision (RSD 9.61%) for the Ni2+ metal ion, using a confidence limit of 98%.
Palavras-chave: Biodiesel
Níquel
Voltametria adsortiva de redissolução
Digestão em micro-ondas
Biodiesel
Nickel
Adsorptive stripping voltammetry
Digestion in a microwave oven
Área(s) do CNPq: CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA
Idioma: por
País: BR
Instituição: Universidade Federal do Maranhão
Sigla da instituição: UFMA
Departamento: QUIMICA
Programa: PROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCET
Citação: NOBRE, Eva Michelly Carvalho Santana. PROCEDURE OPTIMIZED VOLTAMMETRIC FOR DETERMINATION OF Ni2 + IN PRE-TREATED SAMPLES OF BIODIESEL, USING MODIFIED ELECTRODE WITH FILM OF MERCURY. 2011. 71 f. Dissertação (Mestrado em QUIMICA) - Universidade Federal do Maranhão, São Luís, 2011.
Tipo de acesso: Acesso Aberto
URI: http://tedebc.ufma.br:8080/jspui/handle/tede/920
Data de defesa: 4-Jul-2011
Aparece nas coleções:DISSERTAÇÃO DE MESTRADO - PROGRAMA DE PÓS-GRADUAÇÃO EM QUIMICA

Arquivos associados a este item:
Arquivo TamanhoFormato 
dissertacao Eva.pdf1,54 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.