Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://tedebc.ufma.br/jspui/handle/tede/tede/888
Registro completo de metadados
Campo DCValorIdioma
dc.creatorDantas, Luiza Maria Ferreirapt_BR
dc.contributor.advisor1TAKANA, Auro Atsushipt_BR
dc.date.accessioned2016-08-19T12:56:30Z-
dc.date.available2008-09-04pt_BR
dc.date.issued2007-08-22pt_BR
dc.identifier.citationDANTAS, Luiza Maria Ferreira. HYDRAZINE DETERMINATION FOR VOLTAMMETRIC OF SQUARE SHAPED WAVE ON GRAPHITE ELECTRODE MODIFIED WITH FeTPyPz. 2007. 68 f. Dissertação (Mestrado em QUIMICA) - Universidade Federal do Maranhão, São Luis, 2007.por
dc.identifier.urihttp://tedebc.ufma.br:8080/jspui/handle/tede/888-
dc.description.resumoNeste trabalho, a determinação de hidrazina (N2H4) em solução aquosa foi investigada com o uso de técnicas voltamétricas sobre eletrodos de grafite pirolítico (GP), antes e após a modificação com tetrapiridinoporfirazina de ferro (FeTPyPz). O eletrodo modificado GP/FeTPyPz apresentou correntes de oxidação da N2H4 mais acentuadas e com melhor perfil voltamétrico em relação ao eletrodo não modificado. Este eletrodo modificado apresentou dois picos reversíveis atribuídos aos processos redox: Fe(I)TPyPz/Fe(II)TPyPz e Fe(II)TPyPz/Fe(III)TPyPz. As condições de otimização do pH foram realizados em soluções preparadas através da mistura de diferentes proporções de solução de hidróxido de sódio (NaOH) 0,1 mol Lfi1 e tampão fosfato (KH2PO4) 0,1 mol Lfi1, a fim de obter soluções com pH variando de 7 a 13. Com o objetivo de aumentar a sensibilidade para a oxidação de hidrazina, testou-se três técnicas voltamétricas: voltametria cíclica (CV), voltametria de pulso diferencial (DPV), e voltametria de onda quadrada (SWV). Os melhores resultados foram obtitos através da técnica SWV e as condições otimizadas para a determinação de hidrazina foram: i) eletrólito: solução NaOH 0,1 mol Lfi1, ii) frequência de 30 sfi1, amplitude de pulso de 40 mV e incremento de varredura de 8 mV. Sob tais circunstâncias, o eletrodo modificado forneceu uma resposta linear entre 5 e 111 fimol Lfi1, com limite de detecção e quantificação de 0,82 fimol Lfi1 e 2,7 fimol Lfi1, respectivamente. O sensor investigado apresentou valores de desvio padrão relativo para estudos de repetibilidade da amostra e do sensor abaixo de 5%. O sensor foi aplicado em amostras de águas de caldeira e apresentou média de recuperação de 116%.por
dc.description.abstractIn this work, the determination of hydrazine (N2H4) in aqueous solutions was investigated by voltammetric techniques on pyrolytic graphite electrodes (GP) before and after modification with iron tetra-pyridinoporphyrazine (FeTPyPz). The modified electrode GP/FeTPyPz presented higher oxidation currents and better voltammetric profiles in comparison with the unmodified electrodes. This modified electrode exhibited two reversible peaks attributed to the redox processes: Fe(I)TPyPz/Fe(II)TPyPz and Fe(II)TPyPz/Fe(III)TPyPz. The pH optimization conditions were performed in solutions prepared by the mixture of different proportions of 0.1 mol L-1 sodium hydroxide (NaOH) and 0.1 mol L-1 phosphate buffer solutions in order to obtain solutions with pH varying from 7 to 13. In order to increase the sensitivity for hydrazine oxidation, three voltammetric techniques were tested: cyclic voltammetry (CV), differential pulse voltammetry (DPV) and square wave voltammetry (SWV). The best results were provided by the latter one and the optimized conditions for hydrazine determinations were: i) electrolyte: 0,1 mol L-1 NaOH solution; ii) frequency: 30 s-1; pulse amplitude: 50 mV and scan increment: 8 mV. Under such conditions, the modified electrodes provided linear responses ranging from 5 up to 111 μmol L-1, with detection and quantification limits of 0.82 μmol L-1 and 2.7 μmol L-1, respectively. The investigated sensor presented relative standard deviation values for repeatability and reproducibility lower from 5%. The sensor was applied to analyze boiler water samples and a recovery average of 116 % was found.eng
dc.description.provenanceMade available in DSpace on 2016-08-19T12:56:30Z (GMT). No. of bitstreams: 1 Luiza Maria Ferreira Dantas.pdf: 554629 bytes, checksum: e52ab366e6eca5730a202673574f26b5 (MD5) Previous issue date: 2007-08-22eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superiorpt_BR
dc.formatapplication/pdfpor
dc.languageporpor
dc.publisherUniversidade Federal do Maranhãopor
dc.publisher.departmentQUIMICApor
dc.publisher.countryBRpor
dc.publisher.initialsUFMApor
dc.publisher.programPROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCETpor
dc.rightsAcesso Abertopor
dc.subjecthidrazinapor
dc.subjectgrafite pirolíticopor
dc.subjecttetrapiridinoporfirazina de ferropor
dc.subjecthydrazineeng
dc.subjectpyrolytic graphiteeng
dc.subjectiron tetrapyridinoporphyrazineeng
dc.subject.cnpqCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICApor
dc.titleDETERMINAÇÃO DE HIDRAZINA POR VOLTAMETRIA DE ONDA QUADRADA SOBRE ELETRODO DE GRAFITE MODIFICADO COM FeTPyPzpor
dc.title.alternativeHYDRAZINE DETERMINATION FOR VOLTAMMETRIC OF SQUARE SHAPED WAVE ON GRAPHITE ELECTRODE MODIFIED WITH FeTPyPzeng
dc.typeDissertaçãopor
Aparece nas coleções:DISSERTAÇÃO DE MESTRADO - PROGRAMA DE PÓS-GRADUAÇÃO EM QUIMICA

Arquivos associados a este item:
Arquivo TamanhoFormato 
Luiza Maria Ferreira Dantas.pdf541,63 kBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.