dc.creatorMOUCHREK, Charbel Nagib-
dc.creator.Latteshttp://lattes.cnpq.br/2926266392055612por
dc.contributor.advisor1SILVA, Iranaldo Santos da-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1281555528581499por
dc.contributor.referee1SILVA, Iranaldo Santos da-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/1281555528581499por
dc.contributor.referee2TANAKA, Auro Atsushi-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/1460765270568999por
dc.contributor.referee3MELONI, Gabriel Negrão-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/9159760692619178por
dc.date.accessioned2024-02-19T17:20:51Z-
dc.date.issued2023-09-15-
dc.identifier.citationMOUCHREK, Charbel Nagib. Sensor eletroquímico à base de carbon black super-P e ftalocianina de cobalto para detecção de L-cisteína. 2023. 60 f. Dissertação (Programa de Pós-Graduação em Química/CCET) - Universidade Federal do Maranhão, São Luís, 2023.por
dc.identifier.urihttps://tedebc.ufma.br/jspui/handle/tede/tede/5153-
dc.description.resumoNeste trabalho, foi produzido um novo material compósito usando carbon black super-P e ftalocianina de cobalto (CoPc/CBSP). A formação do material compósito foi confirmada por técnicas espectroscópicas (Raman e infravermelho), microscopia eletrônica de varredura e difração de raios X. Esse material foi depositado na superfície do eletrodo de carbono vítreo e suas propriedades de detecção eletroquímica foram verificadas usando a cisteína (CYS), um aminoácido importante e amplamente utilizado na medicina, em aditivos alimentares e cosméticos, como molécula modelo. Estudos por voltametria cíclica revelaram que o eletrodo modificado apresentou propriedades eletrocatalíticas consideráveis (detecção em potencial próximo a 0 V) e um aumento na corrente de pico (12 vezes maior) em relação ao eletrodo não modificado. Quando acoplado ao sistema de análise por injeção em batelada (BIA) com detecção amperométrica, obteve-se ampla faixa linear (1 ‒ 150 μmol L−1 ) e LD na faixa de submicromolar (LOD = 0,133 μmol L−1 ). Testes de repetibilidade (n = 20) em dois níveis de concentração (20 e 40 μmol L−1 ) confirmaram a precisão do método (RSD < 11%). Para avaliar a reprodutibilidade no preparo do sensor, quatro eletrodos diferentes foram testados contra uma solução de concentração 40 μmol L−1 e produziram um erro de 13,5%. O método proposto foi aplicado para a determinação de CYS em amostras farmacêuticas, e a exatidão do método foi avaliada tanto por testes de adição/recuperação (valores entre 89 e 110%), e comparando os resultados pelo método proposto com os obtidos por eletroforese capilar.por
dc.description.abstractIn this work, was produced a novel composite material using carbon black and cobalt phthalocyanine (CoPc/CBSP). Characterizations by spectroscopic techniques (Raman and infrared), scanning electron microscopy, and X-ray diffraction confirmed the formation of the composite material. This material was anchored on the glassy carbon electrode surface, and its electrochemical sensing properties was checked using cysteine (CYS), an important amino widely used in medicine, food additives, and cosmetics, as a model molecule. Preliminary studies by cyclic voltammetry revealed that the modified electrode caused considerable electrocatalytic effects (detection at potential close to 0 V) and an increase in peak current (12-fold) compared to the unmodified electrode. When coupled to the BIA analysis system with amperometric detection, a wide linear range (1 ‒ 150 μmol L−1 ) and adequate detectability (LOD = 0.133 μmol L−1 ) were achieved. Repeatability tests (n = 20) at two concentration levels (20 and 40 μmol L−1 ) confirmed the precision of the method (RSD < 11%). To evaluate the reproducibility of sensor preparation, four different electrodes were tested against a 40 μmol L−1 concentration solution and produced an error of 13.5%. The proposed method was applied for the determination of CYS in pharmaceutical samples, where addition/recovery studies (values between 89 and 110%), as well as results statistically similar to those achieved by capillary electrophoresis, indicated the accuracy and reliability of the electrochemical analyses.eng
dc.description.provenanceSubmitted by Jonathan Sousa de Almeida (jonathan.sousa@ufma.br) on 2024-02-19T17:20:51Z No. of bitstreams: 1 CHARBELNAGIBMOUCHREK.pdf: 1533620 bytes, checksum: bfd49d7a45806738011fa514e38f9bc2 (MD5)eng
dc.description.provenanceMade available in DSpace on 2024-02-19T17:20:51Z (GMT). No. of bitstreams: 1 CHARBELNAGIBMOUCHREK.pdf: 1533620 bytes, checksum: bfd49d7a45806738011fa514e38f9bc2 (MD5) Previous issue date: 2023-09-15eng
dc.description.sponsorshipFAPEMApor
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Federal do Maranhãopor
dc.publisher.departmentDEPARTAMENTO DE QUÍMICA/CCETpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUFMApor
dc.publisher.programPROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCETpor
dc.rightsAcesso Abertopor
dc.subjectanálise por injeção em batelada;por
dc.subjectsensor eletroquímico;por
dc.subjectamperometria.por
dc.subjectBatch injection analysis;eng
dc.subjectelectrochemical sensor;eng
dc.subjectamperometry.eng
dc.subject.cnpqQuímicapor
dc.subject.cnpqCiências Exatas e da Terrapor
dc.titleSensor eletroquímico à base de carbon black super-P e ftalocianina de cobalto para detecção de L-cisteínapor
dc.title.alternativeElectrochemical sensor based on carbon black super-P and cobalt phthalocyanine for detecting of L-cysteineeng
dc.typeDissertaçãopor