dc.creatorSOUSA, Nayane Kédna Freitas de-
dc.creator.Latteshttp://lattes.cnpq.br/5412132658777716por
dc.contributor.advisor1TANAKA, Auro Atsushi-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1460765270568999por
dc.contributor.referee1TANAKA, Auro Atsushi-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/1460765270568999por
dc.contributor.referee2FRANCO, Teresa Cristina Rodrigues dos Santos-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/6219897465386798por
dc.contributor.referee3SILVA, Iranaldo Santos da-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/1281555528581499por
dc.date.accessioned2019-11-20T19:59:40Z-
dc.date.issued2019-08-01-
dc.identifier.citationSOUSA, Nayane Kédna Freitas de. Desenvolvimento de um sensor eletroquímico a base de nanotubo de carbono modificados com ftalocianina de níquel para a determinação do anti-inflamatório diclofenaco. 2019. 45 f. Dissertação (Programa de Pós-Graduação em Química/CCET) - Universidade Federal do Maranhão, São Luís, 2019.por
dc.identifier.urihttps://tedebc.ufma.br/jspui/handle/tede/tede/2921-
dc.description.resumoEste trabalho apresenta o desenvolvimento de um sensor eletroquímico para a determinação voltamétrica do anti-inflamatório diclofenaco (DCF) em soluções aquosas sobre um eletrodo de carbono vítreo modificado com nanotubos de carbono e ftalocianina de níquel (CV/NTC-NiPc). Em solução tampão fosfato salino (pH 7), na varredura anódica de potenciais, o DCF exibiu dois picos de oxidação em potenciais de 0,36 e 0,60 V vs. Ag/AgCl, sendo este último utilizado para as demais análises. Um estudo da dependência da corrente de pico com a concentração de DCF mostrou uma linearidade no intervalo 7,9.10-6 – 1,6.10-5 mol L-1, e limites de detecção e de quantificação encontrados foram de 2.4 μmol L-1 e 7.9 μmol L-1, respectivamente. A quantificação do DCF foi analisada em três diferentes amostras de fármacos e apresentou resultados dentro do permitido pela farmacopéia brasileira. Testes de recuperação foram realizados adicionando-se uma concentração conhecida de uma dessas amostras no DCF padrão, onde os valores de recuperação encontrados foram de 99 a 102%.por
dc.description.abstractThe present work presents the development of an electrochemical sensor for the voltammetric determination of the anti-inflammatory diclofenac (DCF) in aqueous solutions on a glassy carbon electrode modified with carbon nanotubes and nickel phthalocyanine (CV/NTC-NiPc). In phosphate-buffered saline solution (pH 7), in the anodic potential scan, the DCF exhibited two oxidation peaks; the latter being used for the other analyzes. A study of the peak current dependence with the DCF concentration in the range 7.9x10-6 - 1.6x10- 5 mol L-1, and detection and quantification limits of 2.4 μmol L-1 and 7,9 μmol L-1, respectively. DCF quantification was analyzed in three different tissue types and shows results within the limits allowed by the Brazilian pharmacopoeia. Recovery tests were performed by adding known concentration values of a DCF standard solution, and the recovery values ranged from 99 to 102%.eng
dc.description.provenanceSubmitted by Sheila MONTEIRO (sheila.monteiro@ufma.br) on 2019-11-20T19:59:40Z No. of bitstreams: 1 NAYANE-SOUSA.pdf: 1555670 bytes, checksum: 45646337a95e65c34f6e9891bfc7907f (MD5)eng
dc.description.provenanceMade available in DSpace on 2019-11-20T19:59:40Z (GMT). No. of bitstreams: 1 NAYANE-SOUSA.pdf: 1555670 bytes, checksum: 45646337a95e65c34f6e9891bfc7907f (MD5) Previous issue date: 2019-08-01eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpor
dc.description.sponsorshipFundação de Amparo à Pesquisa e ao Desenvolvimento Científico e Tecnológico do Maranhão - FAPEMApor
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico - CNPqpor
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Federal do Maranhãopor
dc.publisher.departmentDEPARTAMENTO DE QUÍMICA/CCETpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUFMApor
dc.publisher.programPROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCETpor
dc.rightsAcesso Abertopor
dc.subjectDiclofenacopor
dc.subjectNanotubos de carbonopor
dc.subjectFtalocianina de níquelpor
dc.subjectSensor eletroquímicopor
dc.subjectDiclofenaceng
dc.subjectCarbon nanotubeseng
dc.subjectNickel phthalocyanineeng
dc.subjectElectrochemical sensor.eng
dc.subject.cnpqEletroquímicapor
dc.subject.cnpqAnálise e Controle e Medicamentospor
dc.titleDesenvolvimento de um sensor eletroquímico a base de nanotubo de carbono modificados com ftalocianina de níquel para a determinação do anti-inflamatório diclofenacopor
dc.title.alternativeDevelopment of a nickel phthalocyanine modified carbon nanotube-based electrochemical sensor for the determination of the anti-inflammatory diclofenaceng
dc.typeDissertaçãopor
Aparece nas coleções:DISSERTAÇÃO DE MESTRADO - PROGRAMA DE PÓS-GRADUAÇÃO EM QUIMICA

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
NAYANE-SOUSA.pdfDissertação de Mestrado1,52 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.