Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://tedebc.ufma.br/jspui/handle/tede/tede/2895
Registro completo de metadados
Campo DCValorIdioma
dc.creatorTEIXEIRA , Erico June Neves-
dc.creator.Latteshttp://lattes.cnpq.br/4958269178279199por
dc.contributor.advisor1MARQUES, Aldaléa Lopes Brandes-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/0121030502015990por
dc.contributor.referee1MARQUES, Aldaléa Lopes Brandes-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/0121030502015990por
dc.contributor.referee2MOUCHREK FILHO, Victor Elias-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/2381183158978639por
dc.contributor.referee3SILVA, Iranaldo Santos da-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/1281555528581499por
dc.date.accessioned2019-11-11T18:15:09Z-
dc.date.issued2019-07-25-
dc.identifier.citationTEIXEIRA, Erico June Neves. Procedimento eletroanalítico para fluoranteno sobre eletrodo de carbono vítreo modificado com ftalocianina de cobalto. 2019. 63 f. Dissertação (Programa de Pós-Graduação em Química/CCET) - Universidade Federal do Maranhão, São Luís.por
dc.identifier.urihttps://tedebc.ufma.br/jspui/handle/tede/tede/2895-
dc.description.resumoEste trabalho propõe um método para a determinação de Fluoranteno (FLU) em meio aquoso com um eletrodo de carbono vítreo modificado por ftalocianina de cobalto (ECV/CoPc), utilizando a Voltametria de Pulso Diferencial (VPD). Parâmetros experimentais foram otimizados para o propósito de determinação de FLU em águas subterrâneas de postos de combustíveis, de São Luis-MA. Sob condições ótimas, o FLU foi determinado usando uma solução tampão Britton-Robinson (BR) 0,3 mol L-1 em pH 2,0 como eletrólito de suporte. A oxidação ocorre entre 1,2 e 1,3V (vs Ag/AgCl). Bons resultados foram obtidos para o limite de detecção (1,41 x 10-6 mol L-1), precisão (RSD de 2,07%) e exatidão (recuperação de 101,43%). Esses resultados indicam que o procedimento proposto se caracteriza como uma boa alternativa para a análise de FLU em águas subterrâneas de postos de combustíveis.por
dc.description.abstractThis work proposes an alternative method for the determination of fluoranthene (FLU) in aqueous solution with a glassy carbon electrode modified by cobalt phthalocyanine (GCE / CoPc), using Differential Pulse Voltammetry (DPV). Experimental parameters were optimized for the purpose of determining FLU in groundwater at gas stations, of São Luis-MA. Under optimal conditions, the FLU was determined using a 0.1 mol L-1 Britton-Robinson (BR) buffer solution at pH 2.0 as supporting electrolyte. Oxidation occurs between 1.2 and 1.3 V vs Ag / AgCl. Good results were obtained for the limit of detection (1.41 x 10-6 mol L-1), precision (RSD of 2.07%) and recovery (101.43%). These results indicate that this procedure is a good alternative for analyzing FLU in groundwater at gas stations.eng
dc.description.provenanceSubmitted by Sheila MONTEIRO (sheila.monteiro@ufma.br) on 2019-11-11T18:15:09Z No. of bitstreams: 1 ERICO-TEIXEIRA.pdf: 1078911 bytes, checksum: 0b286ce633740a7a00b586c907c6a775 (MD5)eng
dc.description.provenanceMade available in DSpace on 2019-11-11T18:15:09Z (GMT). No. of bitstreams: 1 ERICO-TEIXEIRA.pdf: 1078911 bytes, checksum: 0b286ce633740a7a00b586c907c6a775 (MD5) Previous issue date: 2019-07-25eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpor
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Federal do Maranhãopor
dc.publisher.departmentDEPARTAMENTO DE TECNOLOGIA QUÍMICA/CCETpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUFMApor
dc.publisher.programPROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCETpor
dc.rightsAcesso Abertopor
dc.subjectFluorantenopor
dc.subjectÁguas subterrâneaspor
dc.subjectPosto de combustívelpor
dc.subjectVoltametriapor
dc.subjectFluorantheneeng
dc.subjectFuel stationeng
dc.subjectGroundwatereng
dc.subjectVoltammetryeng
dc.subject.cnpqQuímicapor
dc.titleProcedimento eletroanalítico para fluoranteno sobre eletrodo de carbono vítreo modificado com ftalocianina de cobaltopor
dc.title.alternativeFluoranthene electroanalytical procedure on phthalocyanine modified glassy carbon electrode of cobalteng
dc.typeDissertaçãopor
Aparece nas coleções:DISSERTAÇÃO DE MESTRADO - PROGRAMA DE PÓS-GRADUAÇÃO EM QUIMICA

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ERICO-TEIXEIRA.pdfDissertação de Mestrado1,05 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.