Compartilhamento |
|
Use este identificador para citar ou linkar para este item:
https://tedebc.ufma.br/jspui/handle/tede/tede/2895
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | TEIXEIRA , Erico June Neves | - |
dc.creator.Lattes | http://lattes.cnpq.br/4958269178279199 | por |
dc.contributor.advisor1 | MARQUES, Aldaléa Lopes Brandes | - |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/0121030502015990 | por |
dc.contributor.referee1 | MARQUES, Aldaléa Lopes Brandes | - |
dc.contributor.referee1Lattes | http://lattes.cnpq.br/0121030502015990 | por |
dc.contributor.referee2 | MOUCHREK FILHO, Victor Elias | - |
dc.contributor.referee2Lattes | http://lattes.cnpq.br/2381183158978639 | por |
dc.contributor.referee3 | SILVA, Iranaldo Santos da | - |
dc.contributor.referee3Lattes | http://lattes.cnpq.br/1281555528581499 | por |
dc.date.accessioned | 2019-11-11T18:15:09Z | - |
dc.date.issued | 2019-07-25 | - |
dc.identifier.citation | TEIXEIRA, Erico June Neves. Procedimento eletroanalítico para fluoranteno sobre eletrodo de carbono vítreo modificado com ftalocianina de cobalto. 2019. 63 f. Dissertação (Programa de Pós-Graduação em Química/CCET) - Universidade Federal do Maranhão, São Luís. | por |
dc.identifier.uri | https://tedebc.ufma.br/jspui/handle/tede/tede/2895 | - |
dc.description.resumo | Este trabalho propõe um método para a determinação de Fluoranteno (FLU) em meio aquoso com um eletrodo de carbono vítreo modificado por ftalocianina de cobalto (ECV/CoPc), utilizando a Voltametria de Pulso Diferencial (VPD). Parâmetros experimentais foram otimizados para o propósito de determinação de FLU em águas subterrâneas de postos de combustíveis, de São Luis-MA. Sob condições ótimas, o FLU foi determinado usando uma solução tampão Britton-Robinson (BR) 0,3 mol L-1 em pH 2,0 como eletrólito de suporte. A oxidação ocorre entre 1,2 e 1,3V (vs Ag/AgCl). Bons resultados foram obtidos para o limite de detecção (1,41 x 10-6 mol L-1), precisão (RSD de 2,07%) e exatidão (recuperação de 101,43%). Esses resultados indicam que o procedimento proposto se caracteriza como uma boa alternativa para a análise de FLU em águas subterrâneas de postos de combustíveis. | por |
dc.description.abstract | This work proposes an alternative method for the determination of fluoranthene (FLU) in aqueous solution with a glassy carbon electrode modified by cobalt phthalocyanine (GCE / CoPc), using Differential Pulse Voltammetry (DPV). Experimental parameters were optimized for the purpose of determining FLU in groundwater at gas stations, of São Luis-MA. Under optimal conditions, the FLU was determined using a 0.1 mol L-1 Britton-Robinson (BR) buffer solution at pH 2.0 as supporting electrolyte. Oxidation occurs between 1.2 and 1.3 V vs Ag / AgCl. Good results were obtained for the limit of detection (1.41 x 10-6 mol L-1), precision (RSD of 2.07%) and recovery (101.43%). These results indicate that this procedure is a good alternative for analyzing FLU in groundwater at gas stations. | eng |
dc.description.provenance | Submitted by Sheila MONTEIRO (sheila.monteiro@ufma.br) on 2019-11-11T18:15:09Z No. of bitstreams: 1 ERICO-TEIXEIRA.pdf: 1078911 bytes, checksum: 0b286ce633740a7a00b586c907c6a775 (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2019-11-11T18:15:09Z (GMT). No. of bitstreams: 1 ERICO-TEIXEIRA.pdf: 1078911 bytes, checksum: 0b286ce633740a7a00b586c907c6a775 (MD5) Previous issue date: 2019-07-25 | eng |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES | por |
dc.format | application/pdf | * |
dc.language | por | por |
dc.publisher | Universidade Federal do Maranhão | por |
dc.publisher.department | DEPARTAMENTO DE TECNOLOGIA QUÍMICA/CCET | por |
dc.publisher.country | Brasil | por |
dc.publisher.initials | UFMA | por |
dc.publisher.program | PROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCET | por |
dc.rights | Acesso Aberto | por |
dc.subject | Fluoranteno | por |
dc.subject | Águas subterrâneas | por |
dc.subject | Posto de combustível | por |
dc.subject | Voltametria | por |
dc.subject | Fluoranthene | eng |
dc.subject | Fuel station | eng |
dc.subject | Groundwater | eng |
dc.subject | Voltammetry | eng |
dc.subject.cnpq | Química | por |
dc.title | Procedimento eletroanalítico para fluoranteno sobre eletrodo de carbono vítreo modificado com ftalocianina de cobalto | por |
dc.title.alternative | Fluoranthene electroanalytical procedure on phthalocyanine modified glassy carbon electrode of cobalt | eng |
dc.type | Dissertação | por |
Aparece nas coleções: | DISSERTAÇÃO DE MESTRADO - PROGRAMA DE PÓS-GRADUAÇÃO EM QUIMICA |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
ERICO-TEIXEIRA.pdf | Dissertação de Mestrado | 1,05 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.