Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://tedebc.ufma.br/jspui/handle/tede/tede/2858
Registro completo de metadados
Campo DCValorIdioma
dc.creatorSAWCZUK, Raquel Bezerra dos Santos-
dc.creator.Latteshttp://lattes.cnpq.br/0281654133343713por
dc.contributor.advisor1MARQUES, Aldaléa Lopes Brandes-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/0121030502015990por
dc.contributor.referee1MARQUES, Aldaléa Lopes Brandes-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/0121030502015990por
dc.contributor.referee2CAVALCANTE, Kiany Sirley Brandão-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/3810732989135120por
dc.contributor.referee3VARELA JUNIOR, Jaldyr de Jesus Gomes-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/5125904184711352por
dc.date.accessioned2019-09-26T15:23:19Z-
dc.date.issued2019-07-24-
dc.identifier.citationSAWCZUK, Raquel Bezerra dos Santos. Eletrodo de carbono vítreo modificado com nanotubos de carbono e nanopartículas de óxido de ferro na análise simultânea de benzoquinona e catecol em água subterrânea. 2019. 73 f. Dissertação (Programa de Pós-Graduação em Química/CCET) - Universidade Federal do Maranhão, São Luís.por
dc.identifier.urihttps://tedebc.ufma.br/jspui/handle/tede/tede/2858-
dc.description.resumoBenzoquinona (BQ, 1,4-di-hidroxibenzeno) e catecol (CC, 1,2-di-hidroxibenzeno) são subprodutos derivados do benzeno, e são considerados microcontaminantes emergentes devido à sua persistente toxicidade para plantas e animais. Portanto, é de grande importância monitorar esses contaminantes nas águas subterrâneas. Este trabalho propõe um procedimento para determinação de BQ e CC em águas subterrâneas de postos de combustíveis com um sensor voltamétrico baseado em nanotubos de carbono de paredes múltiplas funcionalizados com nanopartículas de carbonilas e óxidos de ferro (NTCPM-COOH / Fe2O3) em solução tampão Britton Robson (BR) 0,1 M pH 5.0, por técnicas de voltametria cíclica (CV) e voltametria de pulso diferencial (DPV). O sensor proposto apresentou um excelente desempenho eletroquímico para a oxidação de BQ e CC. Sob condições experimentais otimizadas, as correntes de pico anódico para a determinação individual dos analitos foram lineares no intervalo de concentração de 4 a 36 μmol L-1 para BQ e CC, com limites de detecção (LD) de 0,99 μmol L-1 e 0,72 μmol L-1, respectivamente. Adicionalmente, as correntes de pico anódico para a determinação simultânea foram lineares na faixa de 12 a 70 μmol L-1, para ambos os analitos. Através das curvas de calibração foram calculados LD: 1,56 (BQ) e 0,97 μmol L-1 (CC). Bons resultados foram obtidos em termos de recuperação (BQ: 99,08%; CC: 96,62), precisão (desvio padrão para BQ: 4,52% e para CC: 5,60%). Estes resultados indicam que este método é suficientemente adequado como um método alternativo para determinar o conteúdo de BQ e CC na água subterrânea.por
dc.description.abstractBenzoquinone (BQ, 1,4-dihydroxybenzene) and catechol (CC, 1,2-dihydroxybenzene) are byproduct derived from benzene, and considered as emerging microcontaminants due to their persistent toxicity for plants and animals. Therefore, it is of great importance to monitor these contaminants in groundwater. This work propose a procedure to determine BQ and CC in undergroundwater of fuel stations with a voltammetric sensor based in a multiwalled carbon nanotubes functionalized with carbonyls and iron oxide nanoparticles (NTCPM- COOH/Fe2O3) in 0.1 M Britton Robson (BR) buffer solution, pH 5.0, by cyclic voltammetric (CV) and differential pulse voltammetry (DPV) techniques. The proposed sensor presented an excellent electrochemical performance for the oxidation of BQ and CC. Under optimized experimental conditions, the anodic peak currents for the individual determination of the analytes were linear in the 4 to 36 μmol L-1 concentration range for both BQ and CC, with limits of detection (DL) of 0.99 μmol L-1 and 0.72 μmol L-1, respectively. Additionally, the anodic peak currents for the simultaneous determination were linear in the range of 12 to 70 μmol L-1, for both analytes. Through the calibration curves it were calculated their DL: 1.56 (BQ) and 0.97 μmol L-1 (CC). Good results were obtained in terms of recovery (BQ: 99.08 %; CC: 96.62% ), precision (standard deviadion for BQ: 4.52 % and for CC: 5.60 %). These results indicate that this method is sufficiently suitable as an alternative method for determining BQ and CC content in underground water.eng
dc.description.provenanceSubmitted by Daniella Santos (daniella.santos@ufma.br) on 2019-09-26T15:23:19Z No. of bitstreams: 1 RaquelSawczuk.pdf: 1103862 bytes, checksum: 8e5c6e8b028bb389c6e280493146c45c (MD5)eng
dc.description.provenanceMade available in DSpace on 2019-09-26T15:23:19Z (GMT). No. of bitstreams: 1 RaquelSawczuk.pdf: 1103862 bytes, checksum: 8e5c6e8b028bb389c6e280493146c45c (MD5) Previous issue date: 2019-07-24eng
dc.description.sponsorshipCAPESpor
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Federal do Maranhãopor
dc.publisher.departmentDEPARTAMENTO DE QUÍMICA/CCETpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUFMApor
dc.publisher.programPROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCETpor
dc.rightsAcesso Abertopor
dc.subjectNanopartículas de óxido de ferropor
dc.subjectNanotubos de carbonopor
dc.subjectÁgua subterrâneapor
dc.subjectBenzoquinonapor
dc.subjectCatecolpor
dc.subjectIron oxide nanoparticleseng
dc.subjectCarbon nanotubeseng
dc.subjectUndergroundwatereng
dc.subjectBenzoquinoneeng
dc.subjectCatecholeng
dc.subject.cnpqQuímica Inorgânicapor
dc.titleEletrodo de carbono vítreo modificado com nanotubos de carbono e nanopartículas de óxido de ferro na análise simultânea de benzoquinona e catecol em água subterrâneapor
dc.title.alternativeModified vitreous carbon electrode with carbon nanotubes and iron oxide nanoparticles for simultaneous analysis of benzoquinone and catechol in groundwatereng
dc.typeDissertaçãopor
Aparece nas coleções:DISSERTAÇÃO DE MESTRADO - PROGRAMA DE PÓS-GRADUAÇÃO EM QUIMICA

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
RaquelSawczuk.pdfDissertação de Mestrado1,08 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.