Compartilhamento |
|
Use este identificador para citar ou linkar para este item:
https://tedebc.ufma.br/jspui/handle/tede/tede/2683
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | SOARES, Leonardo Carvalho | - |
dc.creator.Lattes | http://lattes.cnpq.br/3200985865107967 | por |
dc.contributor.advisor1 | DAMOS, Flávio Santos | - |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/0915687070195770 | por |
dc.contributor.referee1 | DAMOS, Flávio Santos | - |
dc.contributor.referee1Lattes | http://lattes.cnpq.br/0915687070195770 | por |
dc.contributor.referee2 | SILVA, Iranaldo Santos da | - |
dc.contributor.referee2Lattes | http://lattes.cnpq.br/1281555528581499 | por |
dc.contributor.referee3 | ARAÚJO, Adriana Barbosa | - |
dc.contributor.referee3Lattes | http://lattes.cnpq.br/1008844766307732 | por |
dc.date.accessioned | 2019-05-21T19:23:51Z | - |
dc.date.issued | 2019-03-22 | - |
dc.identifier.citation | SOARES, Leonardo Carvalho. Desenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímica. 2019. 81 f. Dissertação (Programa de Pós-Graduação em Química/CCET) - Universidade Federal do Maranhão, São Luis. | por |
dc.identifier.uri | https://tedebc.ufma.br/jspui/handle/tede/tede/2683 | - |
dc.description.resumo | Este trabalho descreve o desenvolvimento de um novo método para a detec-ção de glicose explorando uma célula de análise por injeção em batelada assistida por fotoeletroquímica, projetada e construída com auxílio de tecnologia de impressão 3D. A célula BIA foi acoplada a uma lâmpada LED para controlara a incidência de luz na plataforma fotoeletroativa Cu2O/Ni(OH)2/FTO. As características eletroquímicas da plataforma fotoeletroativa Cu2O/Ni(OH)2/FTO foram avaliadas por voltametria cí-clica, amperometria e espectroscopia de impedância eletroquímica. A célula PEC-BIA apresentou faixa de resposta linear, limite de detecção e sensibilidade de 1 - 1000 μmol L-1, 0,59 μmol L-1, respectivamente. O método PEC-BIA apresentou um valor médio de recuperação de 97,0% a 102,0% quando aplicado à determinação de glicose em amostras de plasma sanguíneo artificial, o que indica desempenho promissor do sis-tema proposto para determinação de glicose. | por |
dc.description.abstract | This work describes the development of a novel method for glucose detection exploiting a photoelectrochemical-assisted batch injection analysis cell designed and constructed with aid of 3D printer technology. The PEC-BIA cell was coupled to a LED lamp in order to control the incidence of light on the Cu2O/Ni(OH)2/FTO photoelectro-active platform. The electrochemical characteristics of Cu2O/Ni(OH)2/FTO photoelec-troactive platform were evaluated by cyclic voltammetry, amperometry and electro-chemical impedance spectroscopy. The PEC-BIA cell presented linear response range, limit of detection and sensitivity of 1 – 1000 μmol L-1, 0.59 mol L-1 and 0.578 A L mol-1, respectively. The PEC-BIA method has presented a mean value of the recovery values of 97.0 % to 102.0% when it was applied to glucose determination in artificial blood plasma samples which indicates the promising performance of the proposed sys-tem to determine glucose. | eng |
dc.description.provenance | Submitted by Sheila MONTEIRO (sheila.monteiro@ufma.br) on 2019-05-21T19:23:51Z No. of bitstreams: 1 Dissertação_Leonardo_Carvalho_Soares.pdf: 2102356 bytes, checksum: deacda83b2c98656345916438964f0ae (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2019-05-21T19:23:51Z (GMT). No. of bitstreams: 1 Dissertação_Leonardo_Carvalho_Soares.pdf: 2102356 bytes, checksum: deacda83b2c98656345916438964f0ae (MD5) Previous issue date: 2019-03-22 | eng |
dc.description.sponsorship | FAPEMA | por |
dc.description.sponsorship | CAPES | por |
dc.description.sponsorship | CNPq | por |
dc.format | application/pdf | * |
dc.language | por | por |
dc.publisher | Universidade Federal do Maranhão | por |
dc.publisher.department | DEPARTAMENTO DE QUÍMICA/CCET | por |
dc.publisher.country | Brasil | por |
dc.publisher.initials | UFMA | por |
dc.publisher.program | PROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCET | por |
dc.rights | Acesso Aberto | por |
dc.subject | Sensor fotoeletroquímico | por |
dc.subject | Glicose | por |
dc.subject | Análise por injeção em batelada | por |
dc.subject | Óxido cuproso (Cu2O) | por |
dc.subject | Hidróxido de Níquel (Ni(OH)2) | por |
dc.subject | Photoelectrochemical sensor | eng |
dc.subject | Glucose | eng |
dc.subject | Batch injection analysis | eng |
dc.subject | Cuprous oxide (Cu2O) | eng |
dc.subject | Nickel Hydroxide (Ni(OH)2) | eng |
dc.subject.cnpq | Química | por |
dc.title | Desenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímica | por |
dc.title.alternative | Development of a system for glucose determination using batch injection analysis by photoelectrochemistry | eng |
dc.type | Dissertação | por |
Aparece nas coleções: | DISSERTAÇÃO DE MESTRADO - PROGRAMA DE PÓS-GRADUAÇÃO EM QUIMICA |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Dissertação_Leonardo_Carvalho_Soares.pdf | Dissertação de Mestrado | 2,05 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.