Tipo do documento: Dissertação
Título: ANÁLISE PROBABILÍSTICA DA CONFORMIDADE DE TENSÃO EM REDES DE DISTRIBUIÇÃO CONSIDERANDO A PRESENÇA DE GERAÇÃO DISTRIBUÍDA.
Título(s) alternativo(s): Probabilistic analysis of voltage conformity in distribution networks considering distributed generation presence.
Autor: VIEIRA, Carlos Henrique da Silva 
Primeiro orientador: SILVA, Maria da Guia da
Resumo: Atualmente há um interesse crescente com relação a problemas de Qualidade de Energia Elétrica (QEE) devido a: introdução de automação em processos industriais; presença de computadores pessoais e dispositivos controlados eletronicamente em instalações residenciais; equipamentos de carga com baixa capacidade para suportar pequenos distúrbios de qualidade de energia; e aumento da percepção dos consumidores industriais e residenciais com relação a distúrbios de QEE. Neste contexto, um aspecto importante com relação a QEE é a conformidade de tensão da rede de distribuição. Ou seja, a adequação da tensão de atendimento aos limites especificados pelos órgãos reguladores. A preocupação com a conformidade de tensão é devido aos seguintes problemas causados por subtensões e sobretensões sustentadas: operação indevida ou com baixa eficiência dos equipamentos elétricos dos consumidores; desligamento de cargas sensíveis; aquecimento de motores de indução devido à subtensões; danos ou falhas em equipamentos devido à sobretensões e aumento nas perdas em vazio nos transformadores causado pela presença de sobretensões sustentadas. Além disso, tem havido diversos incentivos para conexão de Geração Distribuída (GD) na rede de distribuição devido a: incentivo para utilização de sistemas de geração de energia elétrica baseados em fontes de energia renováveis; e livre acesso dos produtores independentes de energia às redes de transmissão e distribuição devido a desregulamentação do setor elétrico. Em princípio, o perfil de tensão de uma rede de distribuição pode ser melhorado com a conexão da GD. Contudo é possível observar deteriorações severas no perfil de tensão de redes de distribuição em cenários pós-falha da GD. Estas falhas são causadas por problemas nos componentes da GD, tais como: sistema de refrigeração, engrenagens, turbina, etc. Durante o período de tempo em que a GD está em reparo, o suporte de potência ativa e reativa da GD, para corrigir o perfil de tensão, está indisponível. Consequentemente, o perfil de tensão tende a se deteriorar enquanto a GD estiver desconectada. Desta forma, é importante realizar estudos para avaliar o impacto da instalação da GD nos índices de conformidade de tensão considerando os seguintes aspectos: indisponibilidade da GD após uma falha intrínseca e a curva de carga. Estes aspectos estão sujeitos a incertezas devido a sua natureza aleatória. Devido a isto, as técnicas mais adequadas para avaliar o impacto de incertezas associadas com flutuações de carga e falhas na GD nos índices de conformidade de tensão são os métodos probabilísticos. A principal vantagem destes métodos é a sua capacidade para combinar severidade e probabilidade para expressar verdadeiramente o risco do sistema. O principal objetivo desta dissertação é o desenvolvimento de um método que modele o comportamento aleatório da rede de distribuição na estimação dos índices de conformidade de tensão através de métodos probabilísticos. Modelos e técnicas para incorporar variações estocásticas na demanda e a indisponibilidade da GD na estimação dos índices de conformidade de tensão são propostos. A técnica proposta nesta dissertação para realizar uma Avaliação Preditiva da Conformidade de Tensão (APCT) se baseia na combinação das seguintes técnicas: fluxo de potência para redes de distribuição radiais via método de soma de correntes; simulação Monte Carlo Quasi-Sequencial e análise de Fourier de séries temporais. O modelo de APCT proposto neste artigo foi testado em um sistema de 32 barras. Os resultados obtidos neste sistema demonstraram que a GD tem um grande potencial para melhorar os índices de conformidade de tensão na rede de distribuição. Contudo, as melhorias mais significativas nos índices de conformidade estão associadas com os pontos de carga mais distantes da subestação. Além disso, pode-se observar que as incertezas associadas com as falhas na GD causam variações significativas nos índices de conformidade de tensão. Adicionalmente, um estudo de sensibilidade demonstrou que os índices de conformidade de tensão são piores (melhores) para sistemas onde a carga é modelada como potência (impedância) constante.
Abstract: Currently, there is growing concern about the Power Quality (PQ) problems due to: introduction of automation in industrial processes, presence of personal computers and electronically controlled devices, load equipments with low capacity to withstand small PQ disturbances and increased perception of residential and industrial consumers with regard to PQ disturbances. In this context, an important issue with relation to PQ is the voltage conformity. That is, the adequacy of service voltage to the limits specified by regulatory agencies. The concern about compliance is due to the following problems caused by sustained undervoltages and overvoltages: improper or less-efficient equipment operation, tripping of sensitive loads, overheating of induction motors due to undervoltages, equipment damage or failure due to overvoltages and higher no-load losses in transformers caused by sustained overvoltages. Furthermore, there have been various incentives for connection of Distributed Generation (DG) in distribution networks due to: incentives for the using of electricity generation based on renewable energy sources and free access of independent energy producers to transmission and distribution networks owing to deregulation of the electric sector. In principle, the voltage profile of a distribution network can be improved with connection of DG. However, it is possible to notice severe deteriorations in the voltage profile of distribution networks in DG post-failure scenarios. These failures are caused by problems in the DG components, such as: cooling system, gears, turbines, etc. During the time period in which the DG is under repair, active and reactive power supports to correct the voltage profile are unavailable. Consequently, the voltage profile tends to deteriorate while the DG is disconnected. In this way, it is important to carry out studies to assess the impact of the DG installation on the voltage conformity indices considering the following issues: DG unavailability after an intrinsic failure and load curve. These aspects are subject to uncertainties due its random nature. Due to this, the most suitable approaches to assess the impact of uncertainties associated with load fluctuations and DG failures on the voltage conformity indices are the probabilistic methods. The main advantage of these methods is its capability to combine severity and probability to truly express the system risk. The main objective of this dissertation is the development of a method that models the random behavior of the distribution network in the voltage conformity indices estimation through the probabilistic methods. Models and techniques to incorporate stochastic variations in the demand and DG unavailability in voltage conformity indices estimation are proposed. The technique proposed in this dissertation to carry a Predictive Assessment of Voltage Conformity (PAVC) is based on the combination of the following techniques: power flow for radial distribution networks via current summation method, Quasi-Sequential Monte Carlo Simulation and Fourier analysis of time series. The PAVC model proposed in this dissertation was tested in 32 buses system. The results obtained with this system demonstrated that the DG has a great potential to improve the voltage conformity indices in the distribution network. However, the most significant improvements in the voltage conformity indices are associated with load points distant from the substation. Furthermore, it can be observed that the uncertainties associated with DG failures cause significant variations in the voltage conformity indices. Additionally, a sensitivity study demonstrated that the voltage conformity indices are worse (better) for systems where the load is modeled as constant power (impedance).
Palavras-chave: Redes de Distribuição de Energia Elétrica; Qualidade de Energia; Geração Distribuída; Conformidade de Tensão; Séries Temporais; Simulação Monte Carlo; Métodos Probabilísticos
Power Distribution Network; Power Quality; Distributed Generation; Voltage Conformity; Time Series; Monte Carlo Simulation; Probabilistic Methods
Área(s) do CNPq: Medição, Controle, Correção e Proteção de Sistemas Elétricos de Potência
Idioma: por
País: Brasil
Instituição: Universidade Federal do Maranhão
Sigla da instituição: UFMA
Departamento: DEPARTAMENTO DE ENGENHARIA DA ELETRICIDADE/CCET
Programa: PROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA DE ELETRICIDADE/CCET
Citação: VIEIRA, Carlos Henrique da Silva. ANÁLISE PROBABILÍSTICA DA CONFORMIDADE DE TENSÃO EM REDES DE DISTRIBUIÇÃO CONSIDERANDO A PRESENÇA DE GERAÇÃO DISTRIBUÍDA.. 2012. [144 folhas]. Dissertação( PROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA DE ELETRICIDADE/CCET) - Universidade Federal do Maranhão, [São Luis] .
Tipo de acesso: Acesso Aberto
URI: http://tedebc.ufma.br:8080/jspui/handle/tede/1866
Data de defesa: 9-Nov-2012
Aparece nas coleções:DISSERTAÇÃO DE MESTRADO - PROGRAMA DE PÓS GRADUAÇÃO EM ENGENHARIA DE ELETRICIDADE

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Carlos Henrique.pdfDissertação de Mestrado3,12 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.