Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://tedebc.ufma.br/jspui/handle/tede/tede/1291
Registro completo de metadados
Campo DCValorIdioma
dc.creatorFARIAS, Julianna Santos-
dc.contributor.advisor1LUZ, Rita de Cássia Silva-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1282444701404832por
dc.date.accessioned2017-04-12T15:30:06Z-
dc.date.issued2017-03-06-
dc.identifier.citationFARIAS, Julianna Santos. DESENVOLVIMENTO DE UM SIMPLES E NOVO SENSOR PARA FLUTAMIDA À BASE DE NANOTUBOS DE CARBONO OXIDADO E ÓXIDO DE GRAFENO: APLICAÇÃO EM AMOSTRAS DE URINA ARTIFICIAL E FORMULAÇÕES FARMACÊUTICAS. 2017. [95 folhas]. Dissertação( PROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCET) - Universidade Federal do Maranhão, [São Luis] .por
dc.identifier.urihttp://tedebc.ufma.br:8080/jspui/handle/tede/1291-
dc.description.resumoEste trabalho descreve o desenvolvimento de um simples e novo sensor eletroquímico para determinação voltamétrica de flutamida em formulações farmacêuticas e amostras de urina artificial empregando um eletrodo de carbono vítreo (ECV) modificado com nanotubos de carbono oxidado e óxido de grafeno (NCO-OG), o qual foi denominado ECV/NCO-OG. As técnicas microscopia eletrônica de varredura (MEV) e a Espectroscopia Raman foram utilizadas para a caracterização dos materiais à base de carbono. A resposta eletroquímica do analito frente ao ECV/NCO-OG foi investigada através das técnicas de voltametria cíclica (VC) e voltametria de onda quadrada (VOQ). O sensor exibiu uma alta atividade eletrocatalítica para a redução da flutamida em 0,05 V vs Ag/AgCl. Os parâmetros experimentais que influenciam a resposta do eletrodo foram investigados e as condições ótimas foram encontradas para o eletrodo modificado com NCO-OG, em solução tampão Britton-Robinson-BR na concentração de 0,1 mol L-1 (pH 5). O sensor proposto apresentou uma ampla faixa de resposta linear de concentração para a flutamida de 0,1 a 1000 µmol L-1 (ou 27,6 µg L-1 a 0,27 g L-1) para n=15 (R2=0,997), com limite de detecção (LOD), limite de quantificação (LOQ), e sensibilidade de 0,03 µmol L-1, 0,1 µmol L-1, e 0,30 µA µmol-1 L, respectivamente. O ECV/NCO-OG foi aplicado com sucesso para a determinação de flutamida em formulações farmacêuticas utilizadas no tratamento de câncer de próstata e amostras de urina artificial. Os resultados obtidos com o sensor proposto foram comparados com o método descrito na literatura e observou-se um nível de confiança de 95%, demonstrando que não há diferença estatística entre o método de referência e o método proposto. Os estudos de adição e recuperação mostram que o método proposto apresenta uma exatidão satisfatória com valor médio de recuperação de 101% ( 1) %. para as amostras fortificadas.por
dc.description.abstractThis paper describes the development of a simple and new sensor electrochemical determination of flutamide in voltamétrica formulations pharmaceutical and artificial urine specimens using a carbon electrode vitreous (ECV) modified with oxidized carbon nanotubes and graphene oxide (NCO-OG), which was named ECV/NCO-OG. Electronic microscopy techniques scanning (SEM) and Raman Spectroscopy were used for the characterization of carbon based materials. The electrochemical response of the analyte front of the ECV/NCO-OG was investigated by cyclic voltammetry techniques (VC) and square wave voltammetry (VOQ). The sensor exhibited a high activity eletrocatalítica for the reduction of flutamide in 0.05 V vs. Ag/AgCl. The parameters experimental influence the response of the electrode was investigated and the optimum conditions were found for the electrode modified with NCO-OG, in Britton-Robinson buffer solution-BR on concentration of 0.1 mol L-1 (pH 5). The proposed sensor presented a wide range of linear response of concentration for the flutamide of 0.1 to 1000 µmol L-1 (or µ g L-1 27.6 to 0.27 g L-1) for n = 15 (R2 = 0.997), limit of detection (LOD), limit of quantification (LOQ), and sensitivity of 0.03 µmol L-1, 0.1 µmol L-1, and 0.30 µmol µA -1 L, respectively. The ECV/NCO-OG was successfully applied to the determination of flutamide in pharmaceutical formulations used in the treatment of prostate cancer and artificial urine samples. The results obtained with the proposed sensor were compared with the method described in the literature and showed a level of 95% confidence, demonstrating that there is no statistical difference between the method of reference and the method proposed. The addition and recovery studies show that the proposed method presents a satisfactory accuracy with average value of 101% recovery ( 1)%. for the fortified samples.eng
dc.description.provenanceSubmitted by Maria Aparecida (cidazen@gmail.com) on 2017-04-12T15:30:06Z No. of bitstreams: 1 Juliana Santos Farias.pdf: 1234303 bytes, checksum: 420e49b91acb05fb1346e95075411509 (MD5)eng
dc.description.provenanceMade available in DSpace on 2017-04-12T15:30:06Z (GMT). No. of bitstreams: 1 Juliana Santos Farias.pdf: 1234303 bytes, checksum: 420e49b91acb05fb1346e95075411509 (MD5) Previous issue date: 2017-03-06eng
dc.description.sponsorshipCAPES, FAPEMA,CNPQpor
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Federal do Maranhãopor
dc.publisher.departmentDEPARTAMENTO DE QUÍMICA/CCETpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUFMApor
dc.publisher.programPROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCETpor
dc.rightsAcesso Abertopor
dc.subjectFlutamida; sensor eletroquímico; nanotubos de carbono oxidado; óxido de grafeno;amostras farmacêuticas; amostra de urinapor
dc.subjectFlutamide; electrochemical sensor; oxidized carbon nanotube; graphene oxide; pharmaceutical samples; urine sampleseng
dc.subject.cnpqInstrumentação Analíticapor
dc.titleDESENVOLVIMENTO DE UM SIMPLES E NOVO SENSOR PARA FLUTAMIDA À BASE DE NANOTUBOS DE CARBONO OXIDADO E ÓXIDO DE GRAFENO: APLICAÇÃO EM AMOSTRAS DE URINA ARTIFICIAL E FORMULAÇÕES FARMACÊUTICASpor
dc.title.alternativeDEVELOPMENT OF A NEW AND SIMPLE SENSOR FOR FLUTAMIDE TO BASE OXIDIZED CARBON NANOTUBES AND GRAPHENE OXIDE: APPLICATION IN ARTIFICIAL URINE SAMPLES AND PHARMACEUTICAL FORMULATIONSeng
dc.typeDissertaçãopor
Aparece nas coleções:DISSERTAÇÃO DE MESTRADO - PROGRAMA DE PÓS-GRADUAÇÃO EM QUIMICA

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Juliana Santos Farias.pdfDissertação de Mestrado1,21 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.