Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://tedebc.ufma.br/jspui/handle/tede/tede/1291
Tipo do documento: Dissertação
Título: DESENVOLVIMENTO DE UM SIMPLES E NOVO SENSOR PARA FLUTAMIDA À BASE DE NANOTUBOS DE CARBONO OXIDADO E ÓXIDO DE GRAFENO: APLICAÇÃO EM AMOSTRAS DE URINA ARTIFICIAL E FORMULAÇÕES FARMACÊUTICAS
Título(s) alternativo(s): DEVELOPMENT OF A NEW AND SIMPLE SENSOR FOR FLUTAMIDE TO BASE OXIDIZED CARBON NANOTUBES AND GRAPHENE OXIDE: APPLICATION IN ARTIFICIAL URINE SAMPLES AND PHARMACEUTICAL FORMULATIONS
Autor: FARIAS, Julianna Santos
Primeiro orientador: LUZ, Rita de Cássia Silva
Resumo: Este trabalho descreve o desenvolvimento de um simples e novo sensor eletroquímico para determinação voltamétrica de flutamida em formulações farmacêuticas e amostras de urina artificial empregando um eletrodo de carbono vítreo (ECV) modificado com nanotubos de carbono oxidado e óxido de grafeno (NCO-OG), o qual foi denominado ECV/NCO-OG. As técnicas microscopia eletrônica de varredura (MEV) e a Espectroscopia Raman foram utilizadas para a caracterização dos materiais à base de carbono. A resposta eletroquímica do analito frente ao ECV/NCO-OG foi investigada através das técnicas de voltametria cíclica (VC) e voltametria de onda quadrada (VOQ). O sensor exibiu uma alta atividade eletrocatalítica para a redução da flutamida em 0,05 V vs Ag/AgCl. Os parâmetros experimentais que influenciam a resposta do eletrodo foram investigados e as condições ótimas foram encontradas para o eletrodo modificado com NCO-OG, em solução tampão Britton-Robinson-BR na concentração de 0,1 mol L-1 (pH 5). O sensor proposto apresentou uma ampla faixa de resposta linear de concentração para a flutamida de 0,1 a 1000 µmol L-1 (ou 27,6 µg L-1 a 0,27 g L-1) para n=15 (R2=0,997), com limite de detecção (LOD), limite de quantificação (LOQ), e sensibilidade de 0,03 µmol L-1, 0,1 µmol L-1, e 0,30 µA µmol-1 L, respectivamente. O ECV/NCO-OG foi aplicado com sucesso para a determinação de flutamida em formulações farmacêuticas utilizadas no tratamento de câncer de próstata e amostras de urina artificial. Os resultados obtidos com o sensor proposto foram comparados com o método descrito na literatura e observou-se um nível de confiança de 95%, demonstrando que não há diferença estatística entre o método de referência e o método proposto. Os estudos de adição e recuperação mostram que o método proposto apresenta uma exatidão satisfatória com valor médio de recuperação de 101% ( 1) %. para as amostras fortificadas.
Abstract: This paper describes the development of a simple and new sensor electrochemical determination of flutamide in voltamétrica formulations pharmaceutical and artificial urine specimens using a carbon electrode vitreous (ECV) modified with oxidized carbon nanotubes and graphene oxide (NCO-OG), which was named ECV/NCO-OG. Electronic microscopy techniques scanning (SEM) and Raman Spectroscopy were used for the characterization of carbon based materials. The electrochemical response of the analyte front of the ECV/NCO-OG was investigated by cyclic voltammetry techniques (VC) and square wave voltammetry (VOQ). The sensor exhibited a high activity eletrocatalítica for the reduction of flutamide in 0.05 V vs. Ag/AgCl. The parameters experimental influence the response of the electrode was investigated and the optimum conditions were found for the electrode modified with NCO-OG, in Britton-Robinson buffer solution-BR on concentration of 0.1 mol L-1 (pH 5). The proposed sensor presented a wide range of linear response of concentration for the flutamide of 0.1 to 1000 µmol L-1 (or µ g L-1 27.6 to 0.27 g L-1) for n = 15 (R2 = 0.997), limit of detection (LOD), limit of quantification (LOQ), and sensitivity of 0.03 µmol L-1, 0.1 µmol L-1, and 0.30 µmol µA -1 L, respectively. The ECV/NCO-OG was successfully applied to the determination of flutamide in pharmaceutical formulations used in the treatment of prostate cancer and artificial urine samples. The results obtained with the proposed sensor were compared with the method described in the literature and showed a level of 95% confidence, demonstrating that there is no statistical difference between the method of reference and the method proposed. The addition and recovery studies show that the proposed method presents a satisfactory accuracy with average value of 101% recovery ( 1)%. for the fortified samples.
Palavras-chave: Flutamida; sensor eletroquímico; nanotubos de carbono oxidado; óxido de grafeno;amostras farmacêuticas; amostra de urina
Flutamide; electrochemical sensor; oxidized carbon nanotube; graphene oxide; pharmaceutical samples; urine samples
Área(s) do CNPq: Instrumentação Analítica
Idioma: por
País: Brasil
Instituição: Universidade Federal do Maranhão
Sigla da instituição: UFMA
Departamento: DEPARTAMENTO DE QUÍMICA/CCET
Programa: PROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCET
Citação: FARIAS, Julianna Santos. DESENVOLVIMENTO DE UM SIMPLES E NOVO SENSOR PARA FLUTAMIDA À BASE DE NANOTUBOS DE CARBONO OXIDADO E ÓXIDO DE GRAFENO: APLICAÇÃO EM AMOSTRAS DE URINA ARTIFICIAL E FORMULAÇÕES FARMACÊUTICAS. 2017. [95 folhas]. Dissertação( PROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCET) - Universidade Federal do Maranhão, [São Luis] .
Tipo de acesso: Acesso Aberto
URI: http://tedebc.ufma.br:8080/jspui/handle/tede/1291
Data de defesa: 6-Mar-2017
Aparece nas coleções:DISSERTAÇÃO DE MESTRADO - PROGRAMA DE PÓS-GRADUAÇÃO EM QUIMICA

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Juliana Santos Farias.pdfDissertação de Mestrado1,21 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.